| Defender Diesel Fire Pump Set | |||
| Model : DEF 45-508 ISAL | |||
| Spesification | |||
| Pump Brand | : Ebara | ||
| Type | : 100x80 FSJA | ||
| Inlet x outlet | : 4" x 3" | ||
| Kapasitas | : Max 800 GPM / 2100 ltr per min | ||
| Head | : 80 Meter | ||
| Engine Brand | : Defender By Isuzu Technology | ||
| Type | : 4BDG | ||
| Admission mehtod | : Natural Aspirated | ||
| Max power | : 66 kw | ||
| Auxiliary pump power | : 47 kw | ||
| Bore * stroke | : 102*118 | ||
| Engine Speed | : 2900 RPM | ||
| Fuel Consumption rate | : 14,2 L/Hour | ||
| Base Plate with Standart Coupled FCL Type | |||
| Fuel Tank 120 Liter | |||
| Flexible and Industrial silencer | |||
| Accu 70 A 24 Volt | |||
| DC control panel refer to NFPA 20 | |||
| 1 set analog tachometer indicator with speed sensor | |||
| 2 set of analog volt meter with 12 or 24 Volt indicator | |||
| 1 set of analog water temperature indicator | |||
| 1 set of analog oil pressure indicator | |||
| Over speed verification button and over speed reset button | |||
| Battery Charge Indicator | |||
| Mode selector for auto-run and manual-run | |||
| Manual stop lift & Hold button | |||
| Manual Crank #1 switch button | |||
| Manual Crank #2 switch button | |||
| Defender Diesel Fire Pump Set | |||
| Model : DEF 45-508 ISAL | |||
| Spesification | |||
| Pump Brand | : Ebara | ||
| Type | : 100x80 FSJA | ||
| Inlet x outlet | : 4" x 3" | ||
| Kapasitas | : Max 800 GPM / 2100 ltr per min | ||
| Head | : 80 Meter | ||
| Engine Brand | : Defender By Isuzu Technology | ||
| Type style='mso-spacerun:yes'> | : 4BDG | ||
| Admission mehtod | : Natural Aspirated | ||
| Max power | : 66 kw | ||
| Auxiliary pump power style='mso-spacerun:yes'> | : 47 kw | ||
| Bore * stroke style='mso-spacerun:yes'> | : 102*118 | ||
| Engine Speed | : 2900 RPM | ||
| Fuel Consumption rate | : 14,2 L/Hour | ||
| Base Plate with Standart Coupled FCL Type | |||
| Fuel Tank 120 Liter style='mso-spacerun:yes'> | |||
| Flexible and Industrial silencer | |||
| Accu 70 A 24 Volt style='mso-spacerun:yes'> | |||
| DC control panel refer to NFPA 20 | |||
| 1 set analog tachometer indicator with speed sensor | |||
| 2 set of analog volt meter with 12 or 24 Volt indicator | |||
| 1 set of analog water temperature indicator | |||
| 1 set of analog oil pressure indicator | |||
| Over speed verification button and over speed reset button | |||
| Battery Charge Indicator | |||
| Mode selector for auto-run and manual-run | |||
| Manual stop lift & Hold button | |||
| Manual Crank #1 switch button | |||
| Manual Crank #2 switch button | |||